The frequency distribution of earliest glaucomatous visual field defects documented by automatic perimetry

2500-3000 eyes with ocular hypertension, with or without established glaucoma in the fellow eye, were followed with automatic perimetry for several years. Forty-five eyes showed a documented change from repeated normal fields to reproducible glaucomatous visual field loss. The location of the defective points in the first pathological field of each eye was registered. The resulting frequency distr

Changes in differential threshold in patients with glaucoma during prolonged perimetry

Patients with chronic open-angle glaucoma and others suspected of having glaucoma were subjected to continuous contrast threshold measurement by automatic and manual perimetric techniques. The results show that an increase of contrast threshold over time is a frequent finding in glaucoma patients and that this increment can be large, especially at points close to existing field defects. it is repr

Visual field and retinal nerve fibre layer in early glaucoma after optic disc haemorrhage

Computerized visual field testing with the Competer automatic perimeter including automatic profile perimetry revealed early glaucomatous field loss in 9 of 10 eyes with photographically demonstrable retinal nerve fibre layer (RNFL) defects after optic disc haemorrhages despite the fact than conventional routine perimetry had failed to do so. In 7 of these cases the Competer central pattern test w

A clinical comparison of three computerized automatic perimeters in the detection of glaucoma defects

The ability to detect glaucomatous field defects of three automatic computerized perimeters (COMPETER, OCTOPUS, and PERIMETRON) was compared in a clinical study of 74 patients. This study included patients with glaucoma, those with suspected glaucoma in whom the visual fields were completely normal, and normal subjects. The reference fields were obtained by careful static and kinetic manual perime

Computerized profile perimetry in glaucoma

The new profile testing mode of the COMPETER automatic perimeter was clinically tested and compared with careful manual profile perimetry on the Tübinger perimeter. Each of 110 patients with glaucomatous field defects, patients with suspected glaucoma, and normal subjects had one meridian tested. All of the 55 patients who showed an abnormal result on the manual profile also had abnormal findings

Computerized visual field screening in the management of patients with ocular hypertension

Visual field testing which the Computer fully automatic computerized perimeter (Heijl & Krakau 1975) employing a supra-liminal screening test procedure was used in a material of 1013 eyes with ocular hypertension in which earlier routine perimetry (kinetic and static) on the Goldmann perimeter had yielded a normal result. The automatic screening was repeated if positive, and manual control per

Automatic perimetry (COMPETER). Ability to detect early glaucomatous field defects

The ability of fully automatic computerized perimetry to detect early glaucomatous field damage was compared with that of careful static and kinetic manual perimetry in a clinical study on 104 patients, 51 of whom had early glaucomatous field defects, 20 of whom were glaucoma suspects with no field defects, and 33 of whom were normal. The automatic perimeter used was the COMPETER automatic perimet

Future contingents, Supervaluationism, and relative truth

The problem of future contingents is one of the most ancient and debated puzzles in Western philosophy, and Supervaluationism is, today, one of the most prominent solutions to the problem. Recently, John MacFarlane has carried a well-known criticism to Supervaluationism (and all other standard approaches to future contingents) and put forward a new solution of the problem of future contingents, wh

Defining Success in International Border Police Collaboration

The risks and insecurities highlighted in contemporary societies have given rise to a diversity of forms of policing; intelligence based policing, and networked based collaboration projects. This study focuses on the collaboration project Turnstone, which was partly funded by the EU. The project was a joint collaboration among border organizations in Estonia, Finland, Latvia, Lithuania, and Sweden

An automatic method for measurements of arterial intima-media thickness using ultrasonic B-mode data

We have previously developed algorithms that use B-mode cineloops for simultaneous measurements of arterial diameter change and longitudinal movement of the arterial wall. In this study the lumen diameter algorithm was extended to also measure arterial intima-media thickness of the far wall. To optimize the algorithm the influence of the lateral width of the region-of-interest (1 pixel, 0.1 mm, 0.

Volumetric Blood Flow Assessment through Multigate Spectral Doppler

Volumetric blood flow measurements require the assessment of both the velocity distribution and the cross-sectional area of the vessel. Unfortunately several difficulties hamper such a measurement in standard approaches. A new dual beam method has been recently introduced in which the Doppler spectral symmetry is exploited to finely orientating the first beam at 90° with respect to the flow, so th