Search results
Filter
Filetype
Your search for "*" yielded 548531 hits
Surface properties of right side-out plasma membrane vesicles isolated from barley roots and leaves
Molecular characterization of a new type of receptor-like kinase (wlrk) gene family in wheat
Cytochrome P-450/420 in plant plasma membranes: A possible component of the blue-light-reducible
Immunoaffinity purification and biochemical characterization of plasma membrane arabino-galactan-rich glycoproteins of Nicotiana glutinosa
Isolation and polypeptide composition of 1,3-ß-glucan synthase from plasma membranes of Brassica oleracea
The l,3‐ß‐glucan synthase (callose synthase, EC 2.4.1.34) was solubilized from cauliflower (Brassica oleracea L.) plasma membranes with digitonin, and partially purified by ion exchange chromatography and gel filtration [fast protein liquid chromatography (FPLC)] using 3‐[(cholamidopropyl)dimethylammonio]‐1‐propane‐sulfonate (CHAPS) in the elution buffers. These initial steps were necessary to obt
Cell-context signalling
In plants, cells differentiate according to their position with relation to their cell neighbours. Monoclonal antibody (MAb) probes to polysaccharide epitopes, present at the surfaces of all plant cells, have defined a family of proteoglycan antigens which signify cellular position. These MAbs have been used to sort the single cells present in carrot somatic cell cultures on the basis of the prese
Nociceptive withdrawal reflexes as a model for spinal nociceptive transmission.
Modular organization of spinal nociceptive reflexes : A New Hypothesis
Recent experimental studies suggest that the nociceptive withdrawal reflex system essentially has a "modular" organization, with each module concerned with the control of a single or a small group of muscles. This organizational principle appears to apply also to some spinoolivocerebellar pathways.
Convergence of afferent paths to olivo cerebellar complexes.
It is now well documented that the cerebellar cortex is divided into sagittal zones which can be identified by their climbing fibre inputs from specific regions of the inferior olive. Each cortical zone sends its efferent fibres, the Purkinje cell axons, to a separate group of neurones in the cerebellar or vestibular nuclei (Oscarsson, 1980, Voogd and Bigare, 1980, Voogd, 1982, Trott and Armstrong
Generisk valideringsmodell för bedömning av reell kompetens för tillgodoräknande som högskoleutbildning (GVTH) samt valideringskriterier för socionomexamen
Denna forskningsrapport sammanfattar resultaten från en studie bedriven inom ramen för Pilotverksamheten för bedömning av reell kompetens (REKO) under ledning av Universitets- och Högskolerådet (UHR). I studien utvecklas:• en generisk valideringsmodell för bedömning av reell kompetens för tillgodoräknande som högskoleutbildning. Valideringsmodellen (av både summativ och formativ karaktär) ska kunn
Discussion on Section III
Summary and conclusions. On the spinal and supraspinal outputs from the superficial dorsal horn.
Role of spontaneous movements in imprinting an action-based body representation in the spinal cord.
Cutaneous Field Stimulation
Fracture toughness of a laminated composite
The fracture toughness of a polymer-metal laminate composite is obtained by mechanical testing of a specimen containing a pre-crack. The laminate is a material used for packaging. It consists of a thin aluminium foil and a polymer coating. A centre cracked panel test geometry is used. Each of the layers forming the laminate is also tested separately. The result is compared with the measured fractuThe fracture toughness of a polymer-metal laminate composite is obtained by mechanical testing of a specimen containing a pre-crack. The laminate is a material used for packaging. It consists of a thin aluminium foil and a polymer coating. A centre cracked panel test geometry is used. Each of the layers forming the laminate is also tested separately. The result is compared with the measured fractu
A model for graded materials with application to cracks
Stress intensity factors are calculated for long plane cracks with one tip interacting with a region of graded material characteristics. The material outside the region is considered to be homogeneous. The analysis is based on assumed small differences in stiffness in the entire body. The linear extent of the body is assumed to be large compared with that of the graded region. The crack tip, incluStress intensity factors are calculated for long plane cracks with one tip interacting with a region of graded material characteristics. The material outside the region is considered to be homogeneous. The analysis is based on assumed small differences in stiffness in the entire body. The linear extent of the body is assumed to be large compared with that of the graded region. The crack tip, inclu
Corrosion crack growth in a bi-material system
Bi-materials composed of thin layers ideally bonded to large substrates are considered. Cracksemerging from an almost flat surface and propagating through the bi-materials are studied.The cracks acquire realistic geometrical shapes, where the tips are integral parts of the cracksurfaces. Crack propagation is related to surface evolution resulting from material loss due tocorrosion. Controlling mecBi-materials composed of thin layers ideally bonded to large substrates are considered. Cracks emerging from an almost flat surface and propagating through the bi-materials are studied. The cracks acquire realistic geometrical shapes, where the tips are integral parts of the crack surfaces. Crack propagation is related to surface evolution resulting from material loss due to corrosion. Controlling
Inverse Analysis for Identification of Elastic/Visco-Plastic Material Constants
In-situ SEM study of fracture of an ultrathin Al-foil-modelling of the fracture processes
Fracture behavior of an ultra thin aluminium foil was studied. For very short crack lengths, fracture has been followed in the scanning electron microscope (SEM) with a tensile stage. A single edge notched tension specimen was used. Crack length and applied load during the crack growth were measured. These results have been used to calculate fracture strength using linear elastic fracture mechanicFracture behavior of an ultra thin Aluminium foil was studied. For very short crack lengths, fracture has been followed in the scanner electronic microscope (SEM) with a tensile stage. A single edge notched tension specimen was used. Crack length and applied load during the crack growth were measured. These results have been used to calculate fracture strength using linear elastic fracture mechani
