Search results
Filter
Filetype
Your search for "*" yielded 529546 hits
Djupt personligt om den svenska romansen före 1900
Recension av Lennart Hedwall: På sångens vägnar. Om svenska sånger och romanser från Joseph Martin Kraus till Josef Eriksson samt några tankar om sång.Kungl. Musikaliska akademiens skriftserie nr 143
Self-Rated Physical Health and Unmet Healthcare Needs among Swedish Patients in Opioid Substitution Treatment
Automatic computerized perimetry in the detection of neurological visual field defects. A pilot study
Forty-seven eyes from 25 patients with neurological disease were examined with an automatic computerized perimeter primarily intended for glaucoma. Manual kinetic and static perimetry with Goldmann's instrument was used for comparison. In 32 fields, the automatic method disclosed all defects that had been found by manual perimetry. Furthermore, it detected three small defects that had been missed
Computer test logics for automatic perimetry
Using an automatic computerized perimeter developed by Heijl & Krakau (1975b) three different perimetric test logics, one simple (I) and two more complicated and time-consuming (II & III) were investigated in practical experiments on healthy normal test subjects and patients and in computer simulated tests. The patients either had a verified diagnosis of glaucoma or glaucoma was suspected.
A note of fixation during perimetry
Small eye movements in the direction of the disappearing stimulus can be observed at kinetic perimetry when the test object enters a scotomatous area. These may be responsible for the fact that several field defects, missed at routine manual perimetry, are spotted at automatic perimetry. In the latter case the patient cannot predict the position of next test light, since these are illuminated at r
Time changes of contrast thresholds during automatic perimetry
Contrast thresholds were continuously recorded in six points of the visual field through a repetitive up-and-down staircase method using the automatic perimeter developed by Heijl & Krakau (1975b). The uninterrupted sessions lasted about 30 min. Nineteen patients with a verified diagnosis of glaucoma, or in whom glaucoma was suspected, and twelve healthy normal subjects were tested. With incre
Studies on computerized perimetry
Automatic perimetry in glaucoma visual field screening. A clinical study
Automatic computerized perimetry was compared to careful manual selective perimetry (a variant of that proposed by Armaly) in 181 eyes of 100 patients from a glaucoma open-care unit. The results of the two methods were very similar. Thus all defects found were identified by the automatic perimeter, and one pathologic field was missed by the manual selective perimetry. The automatic examination gav
An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases
An apparatus for static perimetry of the central visual field at 64 points is described. The testing is fully automatic: the test logic is programmed into a mini-computer and the results are plotted as a diagram in polar coordinates. A few cases with small or medium sized visual field defects have been analyzed by conventional methods and by the automatic instrument with satisfying results.
An automatic static perimeter, design and pilot study
An instrument for automatic static perimetry at 14 points across a meridian was constructed and used in a pilot study. The machine was controlled by a computer and the subjects responded to the light stimuli by pressing one of two push-buttons. Most people investigated readily understood the rules at testing. "Blunders" made by the subject were, however, so common, that allowance had to be made in
A portable hemianopsia tester
A pocket-size static perimeter provided with four test lights, one for each quadrant of the visual field, has been constructed and applied to 190 visual fields in 97 patients. The main advantage of the instrument is its ability to disclose hemianopic defects in bedridden and certain sick patients unable to co-operate with other methods, including the confromtation test. This was performed in 12 fi
Miriam Aida Afrosamba orchestra : É de Lei
Inspelning av Baden Powell´s musik med träblås och stråkkvartett arrangerat av Jayme Vignoli från Rio de Janeiro.
Miriam Aida "Visans Väsen" : Visans Väsen
Svenska visor arrangerade i Brasiliansk stil.
Miriam Aida "Letras ao Brasil" : Letras ao Brasil
Svenska visor med portugiska texter/tolkningar av Guilem Rodruigez da Silva. Arrangerade i Brasiliansk stil.
A Bossa Eletrica : Do Norte
Original musik av gruppens medlemmar i Brasiliansk stil.
A Bossa Eletrica : Eletrificacao
Musik av gruppens medlemmar i Brasiliansk stil.
Sångaren på den tomma spelplatsen – en poetik. : Att gestalta Gilgamesheposet och sånger av John Dowland och Evert Taube
Post-Truth: Hegemony on Social Media and Implications for Sustainability Communication
Contrary to what practice suggests, social media platforms may not be an appropriate forum for communicating with civil society about sustainability issues such as climate change. Misinformation campaigns are distorting the line between fact and falsity on social media platforms, and there has been a profound shift in the way that social media users consume and interact with information. These con